Indoor Models List
Indoor model-level groupings.
query Parameters
refrigerantsstring[] · style: form · explode: trueComma-seperated list of allowed refrigerants (R454B, R32, R32 / R454B)
Headers
Authorizationstring · requiredThe
Authorizationheader is used to authenticate with the API using your API key. Value is of the formatBearer YOUR_KEY_HERE.
Responses
Successful response
modelNumberstring · requiredModel number (model_nomenclature).
mainImagestring · requiredMain product image URL.
namestring · requiredIndoor model name.
typestring · requiredUnit type (e.g., wall-mounted, ducted).
seriesNamestring · requiredProduct series or family name.
refrigerantstring · requiredType of refrigerant used in the unit.
statusstring · requiredLifecycle or availability status of the unit.
descriptionstring · requiredFull description of the unit.
descriptionShortstring · requiredBrief description of the unit.
capacityMinnumber · requiredMinimum nominal cooling or heating capacity.
capacityMaxnumber · requiredMaximum nominal cooling or heating capacity.
minSeer2number · requiredMinimum Seasonal Energy Efficiency Ratio (SEER2).
maxSeer2number · requiredMaximum Seasonal Energy Efficiency Ratio (SEER2).
minEer2number · requiredMinimum Energy Efficiency Ratio (EER2).
maxEer2number · requiredMaximum Energy Efficiency Ratio (EER2).
minHspf2number · requiredMinimum Heating Seasonal Performance Factor (HSPF2).
maxHspf2number · requiredMaximum Heating Seasonal Performance Factor (HSPF2).
minSoundLevelHeatingnumber · requiredMinimum sound pressure level during heating mode.
maxSoundLevelHeatingnumber · requiredMaximum sound pressure level during heating mode.
minSoundLevelCoolingnumber · requiredMinimum sound pressure level during cooling mode.
maxSoundLevelCoolingnumber · requiredMaximum sound pressure level during cooling mode.
isEnergyStarboolean · requiredIndicates ENERGY STAR qualification.
isEconoCoolboolean · requiredIndicates Econo Cool function.
isNanoPlatinumboolean · requiredIndicates Nano Platinum filter feature.
isSwingModeboolean · requiredIndicates Swing Mode availability.
isPowerfulModeboolean · requiredIndicates Powerful Mode availability.
isEnzymeFilterboolean · requiredIndicates Enzyme filter presence.
isIseeSensorboolean · requiredIndicates presence of i-see Sensor.
formFactorstring · requiredProduct form factor (wall, cassette, etc).
Indoor Units List
Indoor unit product object.
query Parameters
refrigerantsstring[] · style: form · explode: trueComma-seperated list of allowed refrigerants (R454B, R32, R32 / R454B)
Headers
Authorizationstring · requiredThe
Authorizationheader is used to authenticate with the API using your API key. Value is of the formatBearer YOUR_KEY_HERE.
Responses
Successful response
skustring · requiredMaterial number (unique product identifier).
srnstring · requiredService reference number (model-based identifier).
modelNumberstring · requiredModel number / internal nomenclature.
modelDescriptionstring · requiredFull description of the unit.
typestring · requiredClassification of the unit (e.g., wall-mounted, ducted).
minSeer2number · requiredMinimum SEER2 value (efficiency rating).
maxSeer2number · requiredMaximum SEER2 value (efficiency rating).
minEer2number · requiredMinimum EER2 value.
maxEer2number · requiredMaximum EER2 value.
minHspf2number · requiredMinimum HSPF2 value.
maxHspf2number · requiredMaximum HSPF2 value.
soundLevelHeatingnumber · requiredMaximum sound pressure level during heating mode.
soundLevelCoolingnumber · requiredMaximum sound pressure level during cooling mode.
refrigerantstring · requiredType of refrigerant used.
depthnumber · requiredPhysical depth (inches).
heightnumber · requiredPhysical height (inches).
widthnumber · requiredPhysical width (inches).
nominalCapacitynumber · requiredNominal cooling or heating capacity.
operationManualstring · requiredURL to the operation manual.
taxonomystring · requiredProduct taxonomy node used for classification.
statusstring · requiredLifecycle or availability status.
compatibleUnitsstring[] · requiredList of compatible units.
heightPackagednumber · requiredPackaged height (inches).
lengthPackagednumber · requiredPackaged length (inches).
widthPackagednumber · requiredPackaged width (inches).
weightPackagednumber · requiredTotal package/shipping weight.
factoryCodestring · requiredInternal factory model code.
factoryUpcstring · requiredUniversal Product Code assigned by factory.
originCountrystring · requiredCountry of origin.
brandstring · requiredCommercial brand.
manufacturerstring · requiredManufacturer's name.
blowerWattsnumber · requiredBlower motor rated power (watts).
minCfmnumber · requiredMinimum airflow (CFM).
maxCfmnumber · requiredMaximum airflow (CFM).
colorstring · requiredExterior color.
minCoolingCap95fnumber · requiredCooling capacity at 95°F (minimum).
hertzinteger · requiredElectrical frequency rating.
inverterboolean · requiredInverter technology presence.
compressorLranumber · requiredCompressor locked-rotor amps (LRA).
mocpIdunumber · requiredMaximum overcurrent protection for indoor unit.
maxPipingHeightnumber · requiredMaximum allowed vertical piping distance.
maxPipingLengthnumber · requiredMaximum allowed piping length.
maxPipingLengthMultizonenumber · requiredMaximum piping length for multi-zone.
meteringDevicestring · requiredType of refrigerant metering device.
minVoltagenumber · requiredMinimum voltage in range.
isEnergyStarboolean · requiredIndicates ENERGY STAR qualification.
isMultiZoneboolean · requiredMulti-zone configuration support.
unitTypestring · requiredUnit type / classification.
seriesstring · requiredProduct series or family name.
Outdoor Models List
Outdoor model-level groupings.
query Parameters
refrigerantsstring[] · style: form · explode: trueComma-seperated list of allowed refrigerants (R454B, R32, R32 / R454B)
Headers
Authorizationstring · requiredThe
Authorizationheader is used to authenticate with the API using your API key. Value is of the formatBearer YOUR_KEY_HERE.
Responses
Successful response
modelNumberstring · requiredModel number (model_nomenclature).
mainImagestring · requiredMain product image URL.
namestring · requiredOutdoor model name.
typestring · requiredUnit type (e.g., wall-mounted, ducted).
seriesNamestring · requiredProduct series or family name.
refrigerantstring · requiredType of refrigerant used in the unit.
statusstring · requiredLifecycle or availability status of the unit.
descriptionstring · requiredFull description of the unit.
descriptionShortstring · requiredBrief description of the unit.
capacityMinnumber · requiredMinimum nominal cooling or heating capacity.
capacityMaxnumber · requiredMaximum nominal cooling or heating capacity.
minSeer2number · requiredMinimum Seasonal Energy Efficiency Ratio (SEER2).
maxSeer2number · requiredMaximum Seasonal Energy Efficiency Ratio (SEER2).
minEer2number · requiredMinimum Energy Efficiency Ratio (EER2).
maxEer2number · requiredMaximum Energy Efficiency Ratio (EER2).
minHspf2number · requiredMinimum Heating Seasonal Performance Factor (HSPF2).
maxHspf2number · requiredMaximum Heating Seasonal Performance Factor (HSPF2).
minSoundLevelHeatingnumber · requiredMinimum sound pressure level during heating mode.
maxSoundLevelHeatingnumber · requiredMaximum sound pressure level during heating mode.
minSoundLevelCoolingnumber · requiredMinimum sound pressure level during cooling mode.
maxSoundLevelCoolingnumber · requiredMaximum sound pressure level during cooling mode.
isEnergyStarboolean · requiredIndicates ENERGY STAR qualification.
isMultiZoneboolean · requiredMulti-zone support.
isHyperHeatboolean · requiredIndicates Hyper Heat feature.
Outdoor Units List
Outdoor unit product object.
query Parameters
refrigerantsstring[] · style: form · explode: trueComma-seperated list of allowed refrigerants (R454B, R32, R32 / R454B)
Headers
Authorizationstring · requiredThe
Authorizationheader is used to authenticate with the API using your API key. Value is of the formatBearer YOUR_KEY_HERE.
Responses
Successful response
skustring · requiredMaterial number (unique product identifier).
srnstring · requiredService reference number (model-based identifier).
modelNumberstring · requiredModel number / internal nomenclature.
modelDescriptionstring · requiredFull description of the unit.
typestring · requiredClassification of the unit (e.g., wall-mounted, ducted).
minSeer2number · requiredMinimum SEER2 value (efficiency rating).
maxSeer2number · requiredMaximum SEER2 value (efficiency rating).
minEer2number · requiredMinimum EER2 value.
maxEer2number · requiredMaximum EER2 value.
minHspf2number · requiredMinimum HSPF2 value.
maxHspf2number · requiredMaximum HSPF2 value.
soundLevelHeatingnumber · requiredMaximum sound pressure level during heating mode.
soundLevelCoolingnumber · requiredMaximum sound pressure level during cooling mode.
refrigerantstring · requiredType of refrigerant used.
depthnumber · requiredPhysical depth (inches).
heightnumber · requiredPhysical height (inches).
widthnumber · requiredPhysical width (inches).
nominalCapacitynumber · requiredNominal cooling or heating capacity.
operationManualstring · requiredURL to the operation manual.
taxonomystring · requiredProduct taxonomy node used for classification.
statusstring · requiredLifecycle or availability status.
compatibleUnitsstring[] · requiredList of compatible units.
heightPackagednumber · requiredPackaged height (inches).
lengthPackagednumber · requiredPackaged length (inches).
widthPackagednumber · requiredPackaged width (inches).
weightPackagednumber · requiredTotal package/shipping weight.
factoryCodestring · requiredInternal factory model code.
factoryUpcstring · requiredUniversal Product Code assigned by factory.
originCountrystring · requiredCountry of origin.
brandstring · requiredCommercial brand.
manufacturerstring · requiredManufacturer's name.
blowerHpnumber · requiredBlower motor horsepower.
blowerSpeedsinteger · requiredBlower motor speeds.
blowerTypestring · requiredBlower motor type.
blowerWattsnumber · requiredBlower motor rated power (watts).
minCfmnumber · requiredMinimum airflow (CFM).
maxCfmnumber · requiredMaximum airflow (CFM).
colorstring · requiredExterior color.
compressorTypestring · requiredCompressor type.
minCoolingCap95fnumber · requiredMinimum cooling capacity at 95°F.
maxCoolingCap95fnumber · requiredMaximum cooling capacity at 95°F.
hertzinteger · requiredElectrical frequency rating.
inverterboolean · requiredIndicates presence of inverter technology.
compressorLranumber · requiredCompressor locked-rotor amps (LRA).
mocpIdunumber · requiredMaximum overcurrent protection for indoor unit.
mocpOdunumber · requiredMaximum overcurrent protection for outdoor unit.
mocpOduBranchboxByOdunumber · requiredMOCP: outdoor unit branch box.
mocpOduSeparatenumber · requiredMOCP: outdoor unit separate spec.
maxPipingHeightnumber · requiredMaximum allowed vertical piping distance.
maxPipingHeightOduAbovenumber · requiredMax piping height (ODU above IDU).
maxPipingHeightOduBelownumber · requiredMax piping height (ODU below IDU).
maxPipingLengthnumber · requiredMaximum allowed piping length.
maxPipingLengthMultizonenumber · requiredMaximum piping length for multi-zone.
meteringDevicestring · requiredType of refrigerant metering device.
phaseinteger · requiredElectrical phase (single-phase, three-phase).
ratedAmpsnumber · requiredNominal current draw (rated load amps).
minVoltagenumber · requiredMinimum voltage in range.
maxVoltagenumber · requiredMaximum voltage in range.
isEnergyStarboolean · requiredIndicates ENERGY STAR qualification.
isMultiZoneboolean · requiredMulti-zone configuration support.
unitTypestring · requiredUnit type / classification.
seriesstring · requiredProduct series or family name.